Ted House, Syracuse, New York




Ted House is a 1200 sq ft house with a radiant heat floor with a 96.5% gas-fired Rannai water heater. The Rannai unit has a separate water circuit to provide space heating. A Fantech HRV will provide balanced ventilation for the house. The house doesn't have a cooling system installed.

How to Use this Page

Monitoring Plan - TED House



Switch To

Display Options

Daily View

Select Date: Select Date from Calendar
Summary Table
Boiler Summary Table
Monthly Summary Table
Boiler Monthly Summary Table
Indoor Temperature Vs. Outdoor Temperature
Hot Water Temperatures
Total House Power
Daily Water Use
Heating Loads
Pump Status
Power Plot




Monday February 11, 2013



Ted House System Summary
Date Percent
Valid
Data
(%)
Total
House
Power
Import
(kWh)
Total
House
Power
Export
(kWh)
Boiler
System
Power
(kWh)
HRV
Power
(kWh)
Feb 11, 2013 100.0 10.9 0.0 2.5 3.0


Monday February 11, 2013



Boiler Summary Table
Formula         [1] [2] [3] [1]+[2]/
([3]*HHV)
Date Pump 1
Status
(min)
Pump 2
Status
(min)
Hot
Water
Use
(gal)
Average
Ventilation
(cfm)
DHW
Load
(MBtu)
Radiant
Floor
Load
(MBtu)
Boiler
Natural
Gas Use
(cf)
Boiler
Efficiency
(%)
Feb 11, 2013 795.2 121.8 0.4 120.7 0.1 115.6 132.0 85.0
1. HHV=1032.


Monday February 11, 2013

Graphical Figure

Monday February 11, 2013

Graphical Figure

Monday February 11, 2013

Graphical Figure

Monday February 11, 2013

Graphical Figure

Monday February 11, 2013

Graphical Figure

Monday February 11, 2013

Graphical Figure

Monday February 11, 2013

Graphical Figure